Sitemap
Newsletters
Local sites
Contact form
Offices
Login
Home
Products
PULSE Analyzer Platform
Hand-held instruments
Transducers and Conditioning
Acoustic Transducers
Microphones
Microphone-preamplifier combinations
Microphones
Preamplifiers
Hydrophones
Binaural headsets
Sound sources
Sound intensity probes
Couplers
Accessories
Vibration transducers
Conditioning and Amplifiers
Calibration
Environment Management Solutions
Vibration Test - Shakers and Controllers
Telecom/Audio Solutions
Calibration Systems
Modal Exciters
Building Acoustics
Room Acoustics
Vibration Meters
Stock Clearance Sale
Test for I-deas
PHOTON+
Share
E-Mail
Print
Microphone-preamplifier combinations
Sound Field
Any
Free-field
Pressure-field
Diffuse-field
Multi-field
Special
Polarization
Any
Ext. polarized
Prepolarized
Input Type
Any
CCLD/IEPE
Classic
Standards
Any
IEC 61094-4 WS1F
IEC 61094-4 WS2F
IEC 61094-4 WS3F
IEC 61094-4 WS1P
IEC 61094-4 WS2P
IEC 61094-4 WS3P
IEC 61094-1 LS1P
IEC 61094-1 LS2P
Frequency range >
-
Hz
Max. SPL >
dB
High-pressure
Array
Outdoor
Surface
Include
Capsules
TEDS/Preamplifier
Both
66
search results displayed by:
25
50
All
Displaying 1 to 25 of 66 matches
1
2
3
of 3
Type number
Dyn. Range
Freq. Range
Sensitivity
4138-A-015 - 1/8-inch pressure-field microphone with Type 2670 preamplifier, 6 Hz to 140 kHz, 200 V polarization
Designed for very high-frequency measurements in confined spaces.
52.2 - 168 dB
6.5 - 140000 Hz
0.56 mV/Pa
4138-B-006 - 1/8-inch pressure-field microphone with Type 2669 preamplifier and adaptor
Designed for very high-frequency measurements in confined spaces.
52.2 - 168 dB
6.5 - 140000 Hz
0.8 mV/Pa
4138-C-006 - 1/8-inch pressure-field microphone with Type 2669 preamplifier, 6 Hz to 140 kHz, 200 V polarization
Designed for very high-frequency measurements in confined spaces.
52.2 - 168 dB
6.5 - 140000 Hz
0.8 mV/Pa
4138-L-006 - 1/8-inch pressure-field microphone with Type 2669 preamplifier, 6 Hz to 140 kHz, 200 V polarization
Designed for very high-frequency measurements in confined spaces.
52.2 - 168 dB
6.5 - 140000 Hz
0.8 mV/Pa
4182 - Probe microphone, 1 Hz to 20 kHz, 200 V polarization
Designed for near-field measurements in small or awkward places or in harsh environments where a conventional microphone would be unsuitable.
42 - 164 dB
1 - 20000 Hz
3.16 mV/Pa
4184 - Weatherproof microphone unit, 20 Hz to 20 kHz
Designed for use in permanent, semi-permanent or portable noise-monitoring systems.
27 - 140 dB
20 - 20000 Hz
12.5 mV/Pa
4188-A-021 - ½-inch free-field microphone with Type 2671 preamplifier, 8 Hz to 12.5 kHz, prepolarized
Designed for measurements in transport noise measurements, architectural acoustics and electro-acoustics.
19 - 138 dB
20 - 12500 Hz
31.6 mV/Pa
4188-A-031 - ½-inch free-field microphone with Type 2699 preamplifier, 8 Hz to 12.5 kHz, prepolarized
Designed for measurements in transport noise measurements, architectural acoustics and electro-acoustics.
21 - 135 dB
8 - 12500 Hz
31.6 mV/Pa
4188-B-001 - ½-inch free-field microphone with Type 2669-B preamplifier, 8 Hz to 12.5 kHz, prepolarized
Designed for measurements in transport noise measurements, architectural acoustics and electro-acoustics.
15.8 - 146 dB
8 - 12500 Hz
31.6 mV/Pa
4188-C-001 - ½-inch free-field microphone with Type 2669-C preamplifier, 8 Hz to 12.5 kHz, prepolarized
Designed for measurements in transport noise measurements, architectural acoustics and electro-acoustics.
15.8 - 146 dB
8 - 12500 Hz
31.6 mV/Pa
4188-L-001 - ½-inch free-field microphone with Type 2669-L preamplifier, 8 Hz to 12.5 kHz, prepolarized
Designed for measurements in transport noise measurements, architectural acoustics and electro-acoustics.
15.8 - 146 dB
8 - 12500 Hz
31.6 mV/Pa
4189-A-021 - ½-inch free-field microphone with Type 2671 preamplifier, 6 Hz to 20 kHz, prepolarized
Designed for high-precision, free-field measurements where a microphone with high sensitivity is required.
16.5 - 134 dB
20 - 20000 Hz
50 mV/Pa
4189-A-031 - ½-inch free-field microphone with Type 2699 preamplifier, 6 Hz to 20 kHz, prepolarized
Designed for high-precision, free-field measurements where a microphone with high sensitivity is required.
16.5 - 134 dB
6.3 - 20000 Hz
50 mV/Pa
4189-B-001 - ½-inch free-field microphone with Type 2669-B preamplifier, 6 Hz to 20 kHz, prepolarized
Designed for high-precision, free-field measurements where a microphone with high sensitivity is required.
15.2 - 146 dB
6.3 - 20000 Hz
50 mV/Pa
4189-C-001 - ½-inch free-field microphone with Type 2669-C preamplifier, 6 Hz to 20 kHz, prepolarized
Designed for high-precision, free-field measurements where a microphone with high sensitivity is required.
15.2 - 146 dB
6.3 - 20000 Hz
50 mV/Pa
4189-L-001 - ½-inch free-field microphone with Type 2669-L preamplifier, 6 Hz to 20 kHz, prepolarized
Designed for high-precision, free-field measurements where a microphone with high sensitivity is required.
15.2 - 146 dB
6.3 - 20000 Hz
50 mV/Pa
4189-W-003 - ½-inch free-field microphone with Type 2671-W-001 preamplifier, 6 Hz to 20 kHz, prepolarized
Designed for high-precision, free-field measurements where a microphone with high sensitivity is required.
16.5 - 134 dB
6.3 - 20000 Hz
50 mV/Pa
4190-B-001 - ½-inch free-field microphone with Type 2669-B preamplifier, 3 Hz to 20 kHz, 200 V polarization
Designed for high-precision, free-field measurements where a microphone with high sensitivity is required.
15 - 148 dB
3.15 - 20000 Hz
50 mV/Pa
4190-C-001 - ½-inch free-field microphone with Type 2669-C preamplifier, 3 Hz to 20 kHz, 200 V polarization
Designed for high-precision, free-field measurements where a microphone with high sensitivity is required.
15 - 148 dB
3.15 - 20000 Hz
50 mV/Pa
4190-L-001 - ½-inch free-field microphone with Type 2669-L preamplifier, 3 Hz to 20 kHz, 200 V polarization
Designed for high-precision, free-field measurements where a microphone with high sensitivity is required.
15 - 148 dB
3.15 - 20000 Hz
50 mV/Pa
4190-L-002 - ½-inch free-field microphone with Type 2269-L preamplifier, 3 Hz to 20 kHz, 200 V polarization with angle adaptor
Designed for high-precision, free-field measurements where a microphone with high sensitivity is required.
15 - 148 dB
3.15 - 20000 Hz
50 mV/Pa
4191-B-001 - ½-inch free-field microphone with Type 2669-B preamplifier, 3 Hz to 40 kHz, 200 V polarization
Designed for all high-precision electro-acoustic measurements and general acoustic measurements where a robust and stable free-field microphone is required.
21.4 - 16 dB
3.15 - 40000 Hz
12.5 mV/Pa
4191-C-001 - ½-inch free-field microphone with Type 2669-C preamplifier, 3 Hz to 40 kHz, 200 V polarization
Designed for all high-precision electro-acoustic measurements and general acoustic measurements where a robust and stable free-field microphone is required.
21.4 - 162 dB
3.15 - 40000 Hz
12.5 mV/Pa
4191-L-001 - ½-inch free-field microphone with Type 2669-L preamplifier, 3 Hz to 40 kHz, 200 V polarization
Designed for all high-precision electro-acoustic measurements and general acoustic measurements where a robust and stable free-field microphone is required.
21.4 - 162 dB
3.15 - 40000 Hz
12.5 mV/Pa
4192-B-001 - ½-inch pressure-field microphone with Type 2669-B preamplifier, 3 Hz to 20 kHz, 200 V polarization
Designed for high-precision coupler measurements or ANSI noise measurements.
20.7 - 162 dB
3.15 - 20000 Hz
12.5 mV/Pa
Share
E-Mail
Print
Home
Markets
Aerospace
Airport Environment
Automotive / Ground Vehicles
Defence
Environmental Noise and Vibration
Telecom and Audio
Wind Energy
Products
PULSE Analyzer Platform
PULSE Overview
What is PULSE?
New Version: Introducing PULSE 16
PULSE Solutions Overview
PULSE data acquisition hardware
Case Studies
Software Maintenance
Download PULSE Software
Hand-held instruments
Transducers and Conditioning
Acoustic Transducers
Vibration transducers
Conditioning and Amplifiers
Calibration
Environment Management Solutions
Vibration Test - Shakers and Controllers
Telecom/Audio Solutions
Audio Analyzers
Telephone Testing
Head and Torso Simulator
Ear and Mouth Simulators
Electroacoustics Accessories
Calibration Systems
Modal Exciters
Building Acoustics
Room Acoustics
Vibration Meters
Stock Clearance Sale
Test for I-deas
A Secure Foundation for I-deas' Future
Support Contacts
Using Test for I-deas with PULSE
Test for I-deas Software Downloads
Applications
Airport Noise
Building Acoustics
Data recording and analysis
Environmental Noise and Vibration
Material Testing
Noise Source Identification
Sound Intensity Mapping
Acoustic Holography
Beamforming
Noise Source Identification with acoustical array
Occupational Health
Pass-by Noise Testing
Production Testing
Repetitive Testing
Room Acoustics
Sound Power
Sound Power Standards
Noise Emission Directives
Sound Quality
Structural Dynamics
Vibration Testing
Urban Noise
Service
Services
Training
Service and support contracts
Software updates and revisions
Calibration services
Hardware maintenance
System modification
Repair
Rental
Product and service warranty
User Support
Downloads
Frequently Asked Questions
Service Request Form
Courses
Training Courses
Webinars
News & Events
News
Waves - Articles and News
Events
Subscriptions
About Us
Contact
About Brüel & Kjær
Corporate Management
Jobs
Quality and Environment
Quality Management
Environmental Management
Regulatory Requirements and Markings
WEEE Information
Product Safety
Legal Notices
Library
Search the Library
Application Notes
Case Studies
Conference Papers
Dictionary
Primers & Handbooks
Technical Reviews
Corporate Site
Australia
Austria
China
Denmark
France
Germany
Italy
Japan
Korea, South
Russian Federation
Spain
Sweden
United Kingdom
United States
Username (email)
Password
Remember my login
What is My Brüel & Kjær ?
Register here
Re-send password
We help our customers measure and manage the quality of sound and vibration in their products and in the environment
Brüel & Kjær Sound & Vibration Measurement A/S.
P +45 77 41 20 00. F +45 45 80 14 05. info@bksv.com
Copyright © Brüel & Kjær. All Rights Reserved.
Corporate Information
Privacy Policy
Legal Notices